Peel Position
Using the optional present sensor, the "Peel position" parameter allows you to
alter the position of the dispensed label relative to the dispense edge.
Normally, with the initial offset value of "0" the label is removed from the carrier
ribbon until only a .08 in or 2 mm wide part of the label still sticks on the ribbon.
Adjustments have to be carried out only once when a present sensor is being
installed. (range from -.33 to +.33 in or -8.4 mm to +8.4 mm)
If the peel position value is positive, the label will be removed further leaving a
smaller strip sticking on the carrier ribbon.
NOTICE !
It is recommended that you alter the parameter for single print jobs via
software (e.g. if an applicator is used and, therefore, the labels have to be
removed completely). The software provides a second value for individual
adjustments.
You may also change this value using the software commands. Any front
panel value and software command value are totaled together for printing.
The current field to be changed is flashing in the display.
5 Cut Position
7 Printhead pos.
6 Peel Position
Peel Position
+ x.x mm
Peel Position
- x.x mm
Peel Position
± 9.x mm
Peel Position
± 0.x mm
Peel Position
± x.9 mm
Peel Position
± x.0 mm
*
*
*
*
*
*
Peel Position
± x.x mm Yes
Peel Position
± x.x mm No
Confirmation
Sign (+ or -)
1/10 mm
mm
Fig. 9 g Set "Peel Position" parameter