CAB Apollo 1 Manual del operador Pagina 161

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 255
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 160
cab Produkttechnik GmbH & Co KG 161
161
[TABLE OF CONTENTS]
[COMMAND LIST][INDEX]
Hermes
Apollo
A-series
This
function is
available
for:
[ESC][i][L][S]
PRODUCT MARKING AND BARCODE IDENTIFICATION
X - Synchronous Peripheral Signal Settings
The X command can be used to control external devices.
X y[;ao] CR
X = Synchronous Peripheral Signal Setting Command
y = Printing coordinate when a signal should be set. Distance from print start
to start of the signal in millimeters or inches. (See the m command for the
measurement settings.
ao= hex nibbles to set or to reset the signal
Function and settings depend on the used printer type and the peripheral connector. Please refer to
the operator´s manual and to the documentation for the optional devices for each printer model.
The "X" command needs to be placed after the definition of the page size ! ("S"- command)
Syntax: